500 kVA · 400 kW · 50 Hz

500 kVA diesel generator, 400 kW prime

Heavy-duty rating for mining, cement, large plants and data centres. Prime 400 kW / standby 440 kW, Cummins, Volvo or Perkins power, silent canopy or walk-in container.

01What a 500 kVA set is for

Direct answer: a 500 kVA diesel generator delivers 400 kW continuous (prime) at 0.8 pf, 400/230 V 50 Hz, with 550 kVA / 440 kW standby. It suits average loads of 280–320 kW — mining and crushing plants, cement lines, large factories, hospital campuses, data halls and utility stations — and is normally specified with bulk fuel storage and a bunded day tank.
1

Typical applications

  • Mining, crushing and drilling operations
  • Cement, steel and processing lines
  • Large manufacturing plants
  • Data halls and telecom core sites
  • Water and wastewater stations
2

Why this rating

  • Carries 300 kW base load with headroom
  • Two units parallel to 800 kW for N+1
  • Fewer units to maintain than 3 × 250 kVA
3

When to step up

  • Sustained load above 320 kW
  • Ambient above 45 °C or altitude above 2000 m
  • Motor starting above 200 kW DOL
  • Grid-code paralleling with the utility

02Specification

Indicative configuration — final datasheet issued per order. 60 Hz version at 480/277 V, or 11 kV via step-up transformer.

ItemSpecification
Prime power (PRP)400 kW / 500 kVA at 0.8 pf
Standby power (ESP)440 kW / 550 kVA at 0.8 pf
Voltage / frequency400/230 V, 50 Hz, 3-phase 4-wire (480 V / 60 Hz optional)
Engine optionsCummins QSX15-G8 · Volvo Penta TAD1642GE · Perkins 2506C-E15TAG2
AlternatorBrushless, single bearing, IP23, class H, 2/3 pitch, parallel-capable
ControllerDeep Sea DSE8610 parallel controller or ComAp InteliGen, AMF + load sharing
Fuel consumption100% load 95 L/h · 75% 72 L/h · 50% 50 L/h
Fuel tank8-hour integral base tank (800 L), lockable, level gauge, bunded option
Noise (silent canopy)76 dB(A) at 7 m
Dimensions (silent)4600 × 1600 × 2300 mm
Weight (silent, wet)≈ 4500 kg
OptionsWalk-in container (CSC), ATS, synchronising panel, remote monitoring, fuel polishing, exhaust to 70 dB(A), engine block heater

Derating: at 2000 m the set behaves like about 440 kVA; at 50 °C ambient like about 480 kVA. On mining sites both usually apply — specify the actual site conditions, not the brochure rating.

03What 400 kW can carry

Load typeTypical allowanceNote
Continuous plant base load280–320 kW70–80% of prime rating
Motor, direct-on-linesingle motor ≤ 200 kWVoltage dip < 15%, no other load at start
Crusher / mill with soft start≤ 250 kWHigh inertia loads need oversize frame
Parallel pair800 kW prime / N+1 at 400 kWSynchronising panel with load sharing
Data hall≤ 320 kWUPS THD and step-load acceptance must be checked

04Export configuration

CE

Compliance

CE with noise marking, EPA Tier 4 Final on request, SONCAP, SASO/SABER, EAC, destination CoC. For mining clients we also prepare a full document pack for site acceptance.

40

Loading

Silent canopy: one unit per 40 ft HQ, or flat-rack for containerised CSC version. Container version can be shipped as a stand-alone unit and lifted directly onto a prepared foundation.

DOC

Documents

English manual set, factory test report at 25/50/75/100% load with video, wiring and foundation drawings, packing list, CO, critical spares list.

SVC

After-sales

Preventive maintenance plan for the first 2000 hours, operator training, remote diagnostics, and a stocked wear-parts kit for remote sites.

05Buyer questions

How much load can a 500 kVA generator carry?

400 kW continuous at 0.8 pf; keep 280–320 kW average for continuous duty. Standby 550 kVA / 440 kW. A single motor up to 200 kW normally starts direct-on-line; above that use soft start or a larger frame.

Fuel consumption per hour?

95 L/h at 100%, 72 L/h at 75%, 50 L/h at 50%. A full day at 300 kW average is roughly 1,500–1,700 litres — plan bulk storage and bunding.

Price range?

Indicative FOB China 2026: USD 38,000–58,000. Volvo and Cummins at the top, Perkins and Weichai mid-range. Containerised CSC versions and parallel panels add USD 4,000–9,000.

Silent canopy or container?

Silent canopy for fixed sites on a concrete foundation accepting 75–76 dB(A). Container (CSC) for remote or mobile sites: self-contained, weatherproof, lifts as one piece, walk-in service space, about 15–25% more expensive.

Specify by site conditions, not by brochure

Send altitude, ambient temperature, motor starting method and the load curve — we return the derated rating, fuel storage sizing and a FOB price.